This section looks at some error messages generated by Q Capture and Q Apply.
If we get an ASN0569E
startup error SIGSEGV
, it means that we have not started the Queue Manager ($ strmqm <QMname>
).
The following is an extract from the Q Capture log showing the error:
2006-02-15-08.52.43.441000 ASN7094E "Q Capture" : "ASN" : "WorkerThread" : The "P2PSUBSTOPPING" signal failed because the XML publication or Q subscription "T10001" has an invalid subtype "B" or an invalid state "G". 2006-02-15-08.52.43.481000 ASN7094E "Q Capture" : "ASN" : "WorkerThread" : The "P2PSUBSTOPPING" signal failed because the XML publication or Q subscription "T30001" has an invalid subtype "B" or an invalid state "G". 2006-02-15-08.52.48.959000 ASN7094E "Q Capture" : "ASN" : "WorkerThread" : The "P2PREADYTOSTOP" signal failed because the XML publication or Q subscription "T10001" has an invalid subtype "B" or an invalid state "I". 2006-02-15...