Studying a go / no go measurement system


Studies to check the accuracy of go / no go measurements systems are run from the Attribute Gage Study (Analytic Method) option. This is found within the Gage Study submenu of Quality Tools.

In this recipe, we will use data for a go / no go plug gage. The upper limit of the gage is 0.25 mm; 11 reference samples are checked 20 times against the gage and the accepted number is recorded.

We will type the data into the worksheet before running the Attribute Gage Study (Analytic Method) option.

Getting ready

Enter the data shown in the following screenshot into a new worksheet in Minitab:

How to do it…

  1. Navigate to Stat | Quality Tools | Gage Study and click on Attribute Gage Study (Analytic Method).

  2. Enter Part into the Part Numbers field.

  3. Enter Reference into the Reference Values field.

  4. Enter Accepted into the Summarized counts field.

  5. Enter Trials into the Number of trials field.

  6. Enter the Upper limit as 0.25.

  7. Click on OK.

How it works…

The output will plot the probability...