Studies to check the accuracy of go / no go measurements systems are run from the Attribute Gage Study (Analytic Method) option. This is found within the Gage Study submenu of Quality Tools.
In this recipe, we will use data for a go / no go plug gage. The upper limit of the gage is 0.25 mm; 11 reference samples are checked 20 times against the gage and the accepted number is recorded.
We will type the data into the worksheet before running the Attribute Gage Study (Analytic Method) option.
Navigate to Stat | Quality Tools | Gage Study and click on Attribute Gage Study (Analytic Method).
Enter
Part
into the Part Numbers field.Enter
Reference
into the Reference Values field.Enter
Accepted
into the Summarized counts field.Enter
Trials
into the Number of trials field.Enter the Upper limit as
0.25
.Click on OK.