In this recipe, we will learn how to set up Cisco UCS 6248UP to Brocade Fabric connectivity.
Prepare one Cisco UCS 5108 Chassis with two installed UCS IOM 2208XP; each UCS IOM is connected to one Cisco UCS 6428UP. Configure two ports on each Cisco UCS 6428UP, as an FC uplink port which is connected to Brocade SAN Fabric (DS-300B) by Fibre Channel cables. The Brocade fabric is an 8 GB SAN Switch. The UCS service profile (defined by two vHBA1/2) is associated with the UCS Server and can boot up the OS successfully. The details are listed in the following diagram:
We assume that the compatibility of the Cisco UCS Fabric Interconnect (FI) and Brocade DS-300B Switch is supported. The FC mode of each FI is End Host:
We need to verify that the NPIV (N_Port ID Virtualization) status of all ports is ON and then issue the
portcfgshow
command on the Brocade command interface by SSH. The NPIV capability parameter will display ON if the NPIV feature is enabled per port, as shown in the following screenshot:Ports 6 and 7 of each Brocade SAN Switch are connected to FI. As each FC uplink of Cisco Fabric Interconnect is 8 GB, ensure that the Brocade Fibre Channel fill pattern is 2. If the Brocade Fibre Channel fill pattern is not 2, it develops interoperability issues between the Cisco UCS Fabric Interconnects and Brocade Fibre Channel Switches. You can issue the
portcfgshow <port number>
command to ensure that the Channel fill pattern is as shown in the following screenshot:If the Channel fill pattern of the port is not 2, you can issue the
portCfgFillword
command to change the fill pattern. The syntax is as follows:portCfgFillword port, mode
Go to Show Interface of General tab of each FC uplink port, and ensure that the Fill Pattern of each FC uplink port on FI is Arbff, as shown in the following screenshot:
Repeat the preceding procedure from Steps 1 to 3 on another FI and Brocade SAN Switch. Make the connection between Cisco UCS FI and the Brocade SAN Switch by two Fibre Channel cables, and then finally the Cisco UCS to Brocade FC Switch connectivity will be completed.
Log in to Brocade SAN Switch by SSH and issue the
switchshow
command; you can see that ports 6 and 7 have 2 NPIV logins, as shown in the following screenshot:Next, issue the
portShow
command on port 6 or 7 to identify the WorldWide Port Names (WWPNs) of the Cisco UCS Server vHBAs that are logged into the Brocade F-port, as shown in the following screenshot:Repeat the preceding procedure from Steps 1 to 2 on another Brocade SAN Switch. After that, you can create the FC zone Brocade SAN Switch for the connection between the Cisco UCS Blade Server and external SAN storage.
The following table lists the comparison of FC uplinks between Cisco UCS and other band Blades: